Aquascape Water Pump Instructions (91023, 91024, 91025 & Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Aquascape Water Pump Instructions (91023, 91024, 91025 &. Aquascape Water Pump Instructions (91023, 91024, 91025 & 91026) Manuel d'utilisation Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 2
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
InstructIons & maIntenance
3
Y
E
A
R
W
A
R
R
A
N
T
Y
G
A
R
A
N
T
I
E
D
E
T
R
O
I
S
A
N
S
3
WATER PUMP SPECS
Model Number 91023 91024 91025 91026
Maximum Flow Rate 70 GPH 90 GPH 180 GPH 320 GPH
Maximum Head
Height
2.1' 2.8' 4.1' 5.6'
Motor Type Mag-Drive Mag-Drive Mag-Drive Mag-Drive
Wattage 3.0W 4.3W 9.3W 17.6W
Amperage 0.037 0.061 0.175 0.339
Power Cord Length 6' 6' 6' 6'
Discharge Hose
Diameter
1/2" 1/2" 1/2" 5/8"
70 GPH
90 GPH
180 GPH
320 GPH
¼” Stepped
Plastic Adapter
¼” Stepped
Plastic Adapter
½” Cylinder
Plastic Adapter
½” Cylinder
Plastic Adapter
5/8” Straight
Adapter Tube
5/8” Bent
Adapter Tube
Impeller
Impeller
Impeller
Impeller
Impeller Cover
Impeller Cover
Impeller Cover
Impeller Cover
Flow Controller
Flow Controller
Intake Screen
Intake Screen
Intake Screen
½” Cylinder
Plastic Adapter
Flow Controller
Intake Screen
Pump 70 gph 90 gph 180 gph 320 gph
Impeller 91028 91029 91030 91031
SPARE PARTS: REPLACEMENT IMPELLERS
INTRODUCTION
CONTENTS & PUMP PARTS:
Water
PumP
VISIT OUR
WEBSITE
DOWNLOAD A
FREE COPY OF
OUR CATALOG
Thank you for choosing the Aquascape Water Pump. At Aquascape,
our goal is to supply our customers with the best valued products in
water gardening. We hope you enjoy your purchase and thank you
for choosing Aquascape. Your Paradise. Our Passion.
®
3 YEAR WARRANTY
The Aquascape Water Pump is guaranteed for three
years from date of purchase. Proof of purchase
required. Warranty does not cover damage
resulting from negligent handling, misuse or lack of
reasonable maintenance or care. Warranty is valid
against defects due to material and the company’s
workmanship only. The sole obligation shall be to replace the defective
unit with a suitable replacement unit. Units should be checked for
proper operation prior to returning as defective. No liability for loss
or damage of any nature or kind, whether arising out of or from the
use of the product, whether defective or not defective, is assumed by
Aquascape, Inc. or its affiliates.
CONTACT US
For more information about our company or products
please visit our website at www.aquascapeinc.com or
call (US) 1-866-877-6637 (CAN) 1-866-766-3426.
SAFETY INFORMATION
WARNING: Risk of electric shock – This pump has not been
approved for use in swimming pool or marine areas.
WARNING: To provide continued protection against risk
of electric shock, connect to properly grounded, ground fault
circuit interrupter (GFCI) outlets only, using the
following guidelines:
(A) Have a qualified electrician install a properly grounded
receptacle outlet, acceptable for outdoor use and protected
from snow and rain.
(B) Inspect cord before using.
(C) Do not use extension cords.
(D) Any wiring of pumps should be performed by a qualified
electrician to ensure code compliance and user safety.
(E) Unplug pump at receptacle outlet when not
in use or before removal from pond.
(F) To reduce risk of electrical shock, all wiring
and junction connections should be made per local codes.
Requirements may vary depending on usage and location.
(G) The power cable should be protected at all times to avoid
punctures, cuts, bruises and abrasions.
(H) Never handle power cords with wet hands.
(I) Do not remove cord and strain relief. Do not connect
conduit to pump.
(J) Do not use power cable to lift pump.
INSTALLATION

overheat the pump and cause it to fail, thus voiding the warranty. DO
NOT OPERATE DRY!

the cover/strainer in place will allow large debris to enter the pump,
causing the pump to fail, voiding the warranty.

impeller or other moving parts.

in pump with power connected.

organic solvents.

necessary, prior to shipment so as to ensure that employees will not be

laws and regulations shall apply.
IMPORTANT! Aquascape, Inc. is not responsible for losses,
injury, or death resulting from a failure to observe these safety
precautions, misuse or abuse of pumps or equipment.
PUMP SPECIFICATIONS
 
 
 
 
See Chart Below
TYPICAL INSTALLATION
This pump is designed to be operated
fully submerged in the water feature.

for your application.


the fountain, ornamental spitter or filter.

protected by a ground fault interrupter.
Once the pump is running and water
circulating through the filter(s) or
waterfalls, check for any fitting or
waterfall leaks where the external
connections are made.
OPERATION AND MAINTENANCE
Inlet Screen Cleaning -
We recommend inspecting your
pump on a regular basis to
ensure it is functioning properly.
If you notice the water flow rate
diminish, it may be due to the
pump’s inlet screen becoming
clogged with debris. In many
cases the clogged screen can
be cleaned by pulling the pump
out of the water to remove
debris from the pump cover. Always disconnect the power before
performing maintenance on the pump.
Internal Pump Cleaning -
If you have thoroughly cleaned
the pump’s inlet screen and still
have diminished flow rates,
then you will need to remove
the impeller cover to inspect the
impeller rotor assembly.
 If your rotor assembly impeller
and internal pump body have
excessive scale build-up, clean
with a mild acid, such as
white vinegar or non-abrasive
calcium, lime and rust remover
product using a sponge or soft-
bristled brush that won’t scratch
impeller. Removing scale build
up will allow your pump to run
like new again.
REPLACING THE IMPELLER ASSEMBLY
The impeller assembly is the only moving part on the pump and will
experience wear and tear. If you’ve cleaned the pump, as described
above, and still experience poor pump performance, it is most likely time to
replace the impeller. Replacing the impeller is extremely easy. Replacement

®
dealer.
Winter Storage – 
desired, but should be removed if shutting down the pump for the winter.
Disconnect the tubing from the discharge fitting and remove the pump
from the pond. Clean the pump and inlet screens with fresh water and
store the pump in a frost-free location.
Water
PumP
TABLE TOP FOUNTAIN,
SPITTER AND STATUARY
SUBMERSIBLE PUMP
For Models:
• 70 GPH (Item #91023)
• 90 GPH (Item #91024)
• 180 GPH (Item #91025)
• 320 GPH (Item #91026)
For more information about our company or products,
please visit our website at www.aquascapeinc.com
or call us at (US) 1-866-877-6637 (CAN) 1-866-766-3426
©2012 Aquascape, Inc. All Worldwide Rights Reserved 91027.122011
TROUBLESHOOTING
• Reduced Water Flow
Pump or plumbing may be clogged. It may be necessary to clean
the pump intake screen and impeller
Pump Hums and Doesn’t Push Water
Pump or plumbing may be clogged. It may be necessary to clean
the pump intake screen and impeller
Remove the intake screen and impeller cover and inspect and
clean the impeller rotor assembly and internal pump body
Make sure nothing is blocking or wrapped around the impeller
Make sure the pump is receiving the correct voltage
Pump Not Working
The ground-fault circuit-interrupter (GFCI) may have tripped
The pump is not receiving the correct voltage
Vue de la page 0
1 2

Résumé du contenu

Page 1

InstructIons & maIntenance3 YEAR WARRANTYGARANTIE DE TROIS ANS3WATER PUMP SPECSModel Number 91023 91024 91025 91026Maximum Flow Rate 70 GPH 90 GPH

Page 2 - PomPe à eau

3 YEAR WARRANTYGARANTIE DE TROIS ANS3RENSEIGNEMENTS DE SÉCURITÉMISE EN GARDE : risque de choc électrique – Cette pompe n’a pas été approuvée pour une

Commentaires sur ces manuels

Pas de commentaire